| S.No. |
Group of Products, materials or items tested |
Specific Tests or types of tests performed |
Specification, Test Method & Year of Publication |
Limit of Detection |
MU+ |
| 1. |
Ambient air monitoring Fugitive emission monitoring, Solid particulate matter, Gaseous pollutants |
Suspended Particulate Matter |
IS-5182-P-4-2005 |
5-15000ug/m3 |
+6% |
| 2. |
Particulate Matter < 10mu |
IS-5182-P-23-2006 |
5-15000ug/m3 |
+6% |
| 3. |
Particulate Matter < 2.5mu |
40 CFR USEPA Chapter 1-Part 50 AP-L |
5-5000ug/m3 |
+6% |
| 4. |
SO2 |
IS-5182-P-2-2001 |
4-1000ug/m3 |
+5% |
| 5. |
NO2 |
IS-5182-P-6-2006 |
9-740ug/m3 |
+5% |
| 6. |
Ozone |
IS-5182-P-9-1974 |
19.6-19620ug/m3 |
+5% |
| 1. |
Stack emission monitoring |
SPM |
IS-11255-P-1-2009 |
5-20000 mg/Nm3 |
+6% |
| 2. |
SO2 |
IS-11255-P-2-2009 |
5-5000 mg/Nm3 |
+5% |
| 3. |
NOx |
IS-11255-P-7-2005 |
5-5000 mg/Nm3 |
+5% |
| 4. |
CO2 |
IS-13270-1992 |
0.2-25% |
+7% |
| 5. |
O2 |
IS-13270-1992 |
0.2-25% |
+7% |
| 6. |
CO |
IS-13270-1992 |
0.2-25% |
+7% |
| 7. |
Flouride |
Method 13A (EPA Stationary Source Sampling Method) June 20, 1980 |
0-1.4ug/ml |
+6% |